Installation


Articles

Sort by: Page 4 of 6 | Previous | 1 2 3 4 5 6 | Next
DateTitleAuthorType
24 Jul 2000 InterBase version 3.3 product releases
Lists all platforms InterBase 3.3 was released on
Borland Staff FAQ
24 Jul 2000 Client application doesn't see events if NT Service Pack 2 or 3 is installed
Installing later service pack should resolve the problem
Borland Staff FAQ
24 Jul 2000 When installing BDE based products they overwrite IB v5 gds32.dll with v4.2.1 dl
Rename gds32.dll before and after BDE install to alleviate the problem
Borland Staff FAQ
24 Jul 2000 Deploying InterBase v5.0 and why the file msvcrt.dll is needed
Without msvcrt.dll installed gds32.dll will not run.
Borland Staff FAQ
24 Jul 2000 Error installing from InterBase: String variable is not large enough for strin
Trying to install InterBase 4.2.1 from the JBuilder 1 CD produces error message.
Borland Staff FAQ
24 Jul 2000 Trying to install InterBase from the C++Builder CD and I dont have ID / Key info
The Certification ID and the Certification Key needed by the setup program are located in the file ibkey.txt in /IB5/ on the CD-ROM.
Borland Staff FAQ
24 Jul 2000 Installing on SCO failed with error "unrecognized distribution"
The above error is generated because one tries to install SC-V4.0C kit on a SCO 5 machine.
Borland Staff FAQ
24 Jul 2000 How big is the Windows InterBase installation foot print?
A full installation is roughly 27908.6 kb.
Borland Staff FAQ
24 Jul 2000 What are the system requirements for InterBase v5.x
The suggested system requirements for the shipping versions of v5.x are:
Borland Staff FAQ
24 Jul 2000 What Administration Tools ship with your Windows based Server Product
Note: This information pertains to the InterBase kit for Windows 95/NT.
Borland Staff FAQ
24 Jul 2000 fatal lock manager error: Semop failed, errno=22
This error is due to running out of semaphores or shared memory.
Borland Staff FAQ
24 Jul 2000 fatal lock manager error: Semop failed, errno=28 [-no space left on device]
This error is due to running out of semaphores or shared memory.
Borland Staff FAQ
24 Jul 2000 fatal lock manager error: inconsistent lock table version number
Possible cause is an application that was compiled or linked with another version of InterBase, one that had a different lock table version.
Borland Staff FAQ
24 Jul 2000 fatal lock manager error: invalid lock id() errno=??
The meaning of this error isn't always the same.
Borland Staff FAQ
24 Jul 2000 ODS Downgrade
Is it possible to downgrade from ODS 9.0 to ODS 8.0?
Borland Staff FAQ
24 Jul 2000 Error: cannot format message 14:0, message text not found
If you get this error message in standard output, it normally means one of the following:<BR>a) Improper installation of a new kit when previous version kit exists<BR>b) Interbase.msg file is corrupted.<BR>c) Wrong interbase.msg file; because of issue a
Borland Staff FAQ
24 Jul 2000 The system cannot find the path specified
While trying to run the Database Statistics on a database I get an error.
Borland Staff FAQ
24 Jul 2000 ODBC doesn't display time portion of the InterBase date
Can't display the whole date (date & time) via the 16-bit ODBC driver by InterSolv.
Borland Staff FAQ
24 Jul 2000 Escape clause {oj} fails to function
Escape clause {oj} fails to function since upgrade to ODBC driver version 2.00.903.
Borland Staff FAQ
24 Jul 2000 Registry key that tells where IB looks for the license file
HKEY_LOCAL_MACHINE | Software |InterBase Corp | Interbase| Current Version determines where InterBase is installed
Borland Staff FAQ

Server Response from: ETNASC03