Deployment


Articles

Sort by: Page 2 of 7 | Previous | 1 2 3 4 5 6 7 | Next
DateTitleAuthorType
24 Jul 2000 Connecting to the InterBase server displays the Dial-up Connection dialog
A couple different solutions to this problem
Borland Staff FAQ
24 Jul 2000 connection rejected by remote interface
InterBase is not certified for a v5 client to talk to a v3.3 server.
Borland Staff FAQ
12 May 2004 Converting the trial install into a server install
Before InterBase 7.1, it was quite easy to convert the trial to a full server install. Now it isn't so easy.
Quinn Wildman FAQ
29 Mar 2001 Custom installation of Interbase 6.0
My installer for Interbase 6.0 gets an error during installation, "Unable to Copy File".
Justin Swett FAQ
14 Jul 2003 Deadlock errors: cause and resolution
What causes deadlock errors and how to handle them.
Ben Matterson FAQ
24 Jul 2000 Distributing InterBase databases on CD
I need to distribute a database on CD. Is this possible with InterBase?
Borland Staff FAQ
16 Feb 2005 Documentation for RDB$USERS
RDB$USERS is new system table introduced in InterBase 7.5
Quinn Wildman FAQ
24 Jul 2000 Does InterBase set the remote buffer size?
For Interber 5.0., 5.11 is is hard coded. It is configurable in later versions.
Borland Staff FAQ
21 Jul 1999 Embedding InterBase 6.0 in 10 easy steps--InterBase Install and Licensing APIs
InterBase 6 has a new install API that automates many chores involved in embedding the database into an application. This session describes the API and how to use it.
Borland Developer Support White Paper
24 Jul 2000 Error Message: statement failed -902 operating system directive semget failed.
Increasing the system available sephaphores may resolve the problem
Borland Staff FAQ
24 Jul 2000 Error Message: statement failed sql code -104, lock manager out of room
Increasing shared memory may resolve the problem
Borland Staff FAQ
24 Jul 2000 Error: cannot format message 14:0, message text not found
Possible causes:<ul><li>Improper installation of a new kit when previous version kit exists</li><li>Interbase.msg file is corrupted.</li><li>Wrong interbase.msg file (because of situation described above</li></ul>
Borland Staff FAQ
24 Jul 2000 fatal lock manager error: inconsistent lock table version number
Possible cause is an application that was compiled or linked with another version of InterBase, one that had a different lock table version.
Borland Staff FAQ
24 Jul 2000 fatal lock manager error: invalid lock id() errno=??
The meaning of this error isn't always the same.
Borland Staff FAQ
24 Jul 2000 fatal lock manager error: Semop failed, errno=22
This error is due to running out of semaphores or shared memory.
Borland Staff FAQ
24 Jul 2000 fatal lock manager error: Semop failed, errno=28 [-no space left on device]
This error is due to running out of semaphores or shared memory.
Borland Staff FAQ
24 Jul 2000 Features of the evaluation licenses
Evaluation licenses have limited lifetime and limited features
Borland Staff FAQ
24 Jul 2000 General Information on error number 146
5 possible causes for error 146.
Borland Staff FAQ
24 Jul 2000 getting error "I/O error for file: printer out of paper" when using NT
There are two known problems:<ul><li>System is running out of temp space</li><li>The environment variables TEMP and/or TMP have not been defined.</li></ul>
Borland Staff FAQ
24 Jul 2000 Getting Error: fatal lock manager error -semop failed (acquire) errno 28
This error occurs when the InterBase tries to acquire semaphores for use with<br>the lock table and the operating system returns an error.
Borland Staff FAQ

Server Response from: ETNASC01